Seating:
Total 981 Main Floor: 748 Balcony: 231
Stage
Dimensions:
Proscenium Width...................................................................... 49'-10"
Proscenium Height..................................................................... 30' - 0"
Plaster Line to Pit....................................................................... 6' - 1"
Plaster Line to Pit Rail at Center................................................. 15' - 9"
Plaster Line to U. S. Wall at Center............................................. 36' - 0"
Center Line to S.L. Wall............................................................. 48' - 8"
Center Line to Pin Rail S.R. Wall................................................. 40' - 7"
Orchestra Pit Depth @ Stage........................................................ 8' - 0"
Stage Height from House Floor..................................................... 3' - 1"
Stage Height & Row F Height........................................................ 0' - 0"
Grid Height................................................................................ 64' - 2"
Floor
1 1/2" Vertical grain southern yellow pine on two opposing layers of 1/2 " plywood with a base of 2" x 4" sleepers on neoprene pads. Excellent for dance. Floor does not have traps, and the theatre does not own a vinyl dance floor. With prior permission from the technical director, 6d nails and deck screws may be used, and holes up to 1/2 " may be drilled providing they are removed and plugged with hardwood dowels.
Note: Masking tape is not to be used on the stage floor. Vinyl tape, gaffer's tape and cloth spike tape are acceptable if removed after the event.
Stage Access
DSL: 3' x 7' to piano storage and SL entrance to orchestra pit
USL: 3' x 7' to crossover, scene shop, and dressing rooms
USL: 8' x 14' to scene shop and loading dock
USR: 3' x 7' to crossover, green room, and dressing rooms
Orchestra Pit
SR to SL: 40' - 2"
Depth: 8'
DS to US: 9' - 8" with 4' - 1" additional under stage
Access: Doors at either end of the pit lead to S.R. and S.L. corridor. S.R. exit is equipped with a wheelchair lift rated for 300 lbs.
CARPENTER
Low Trim..................................................................................3' - 1"
High Trim............................................................................... 63' -1"
Loading Bridge Height.............................................................. 57' - 0"
Crossing Bridge Height............................................................ 28' - 0"
Proscenium to S.L. Wall........................................................... 23'-10"
Proscenium to S.R. Wall...........................................................16' - 0"
Pit Cover
Wenger Showmaster No lift. Requires two week notice and fee for removal. (one height)
Soft Goods
(see line plot for standard dress)
Main Curtain
Medium gray Velour
Manually operated as traveler from S.L. or guillotine from S.R.
Valance is 32' 0" and can be used as a manual guillotine from S.R.
House Drapery
All House Drapery is black velour with 50% box pleat fullness
Traveler (1) - Two sections 32' 0" x 34' 0" 22' - 0" US from plaster line
Legs (4 pair) - 32' 0" x 12' 0"
Borders (3) - 12' 0" x 65' 0"
Rear curtain (Blackout) (1) - Two sections 32' 0" x 34' 0"
Scrim (1) - Black seamless sharktooth 30' 0" x 65' 0"
Cyclorama (1) - Natural muslin 30' 0' x 65' 0"
Load-in
Loading Dock
Located on the east side of the building at the southeast corner
Loading Dock: Height: 4' - 4"
Width: 27'- 0"
Depth: 14' - 0"
The loading dock is serviced by a 105' long x 26' wide concrete and compacted gravel drive that can accommodate two trucks. Trucks may remain in the load-in area
Load in door
The loading dock services two entrances:
10' X 10' Overhead door
6' X 10' Double door
Both doors provide direct access to the stage and a large storage area.
Parking
Two vehicles may remain parked in gravel portion of the loading area if drivers are nearby (HFAC) or keys remain in the vehicles. A parking lot 75 yards from the theatre is available for truck parking.
Note: Private vehicles must be moved after unloading.
Unauthorized vehicles will be towed at the owner's expense.
Additional Information
The technical director must approve any and all use of pyrotechnics or open flame. In addition a permit for pyrotechnics MUST BE OBTAINED from both the Kentucky State Fire Marshal and the City of Henderson. A demonstration of the effect will be required from the local fire marshal to determine the safety of the device and its use.
STANDARD LINE PLOT
|
|
|
|
|
|
|
|
LINE |
STANDARD DRESS |
DISTANCE FROM |
DISTANCE FROM |
|
|
PLASTER LINE |
PREVIOUS BATTON |
A. |
Fire Curtain |
0' - 2 1/2" |
N/A |
1 |
Valance * |
1' - 0" |
0' - 9 1/2" |
2 |
Main Drape * |
2' - 0" |
1' - 0" |
3 |
1st Electric ** |
2' - 6" |
1' - 6" |
4 |
Cinema Screen * |
4' - 0" |
1' - 6" |
5 |
Open |
4' - 6" |
0' - 6" |
6 |
1 st Clouds*** |
5' - 6" |
1' - 0" |
7 |
Legs |
6' - 6" |
1' - 0" |
8 |
Open |
7' - 0" |
0' - 6" |
9 |
2nd Electric ** |
8' - 6" |
1' - 6" |
10 |
Open |
10' - 0" |
1' - 6" |
11 |
Open |
11' - 0" |
1' - 0" |
12 |
2nd Clouds*** |
13" - 0" |
2' - 0" |
13 |
Legs |
14' - 0 |
1' - 0" |
14 |
Open |
14' - 6" |
0' - 6" |
15 |
Open |
16' - 0" |
1 - 6" |
16 |
3rd Electric |
18' - 0" |
2' - 0" |
17 |
Open |
20' - 0" |
2' - 0" |
18 |
Traveler * |
21' - 6" |
1' - 6" |
19 |
Open |
23' - 6" |
2' - 0" |
20 |
3rd Clouds*** |
25' - 0" |
1' - 6" |
21 |
Open |
25' - 6" |
0' - 6" |
22 |
|
26' - 0" |
0' - 6" |
23 |
Open |
27' - 6" |
1' - 6" |
24 |
Open |
28' - 6" |
1' - 0" |
25 |
4th Electric ** |
30' - 0" |
1' - 6" |
26 |
Open (small screen) |
32' - 0" |
2' - 0" |
| 27 |
Cyclorama |
32' - 6' |
0'- 6 |
| 28 |
Back Blackout |
33' - 0 |
0' - 6 |
|
|
|
|
* Will not be Removed |
|
|
** Only flys to 40'-0" |
|
|
*** Removable with advance notice |
|
6' - 0" from line 27 to back wall |
|
|
Traveler floor blocks SL |
|
|
Arbor Capacity: 750 lbs |
ELECTRICAL
Light Booth:
Located back-of-house approx. 95' from the plaster line under the balcony.
Power:
400 Amp 3 Phase, 120/208V disconnect on SR for touring company use.
1 Spare 100 Amp 3 Phase breaker and 1 60 Amp 3 Phase Breaker at loading dock .
Note: Facility does not have a spare cable to run to bus.
Dimmers:
294 2.4 KW EDI SPI Dimmers dedicated to performance lighting. DMX
Control:
Main console: EDI Enact 400 memory console. 4 pages of 24 playbacks that can be used as submasters, 400 channels, and 2 SVGA monitors.
Stage ManagerÕs console: EDI PLUS. Can be used as a 2-scene preset with 4 pages of 12 channels or as a 1-scene console with 4 pages of 24 channels. Also has 4 pages of 12 submasters and effects package.
House Lights:
Two locations. Automatic dimming from light booth. Manual dimming form backstage left. Step lights must remain on during performance.
Note: Extra crew is needed if house lights are to be dimmed from back stage.
Cable:
1142 feet of three pin cable available.
Trees:
8 - 10' trees. No side arms are available
Circuits:
294 2.4 dimmer per circuit (20 AMP grounded stage pin)
FOH Positions:
FOH 1 3' - 8" from the proscenium. This position is directly over the apron and can only be used for down and steep side light. +28' - 0" from stage 0' - 0".
FOH 2 24' - 2" from the proscenium. Mid-stage throw is approximately 44' - 0" at 30 degrees. + 38' - 0" from stage 0' - 0".
FOH 3 60' - 4" from the proscenium. Mid-stage throw is approximately 87' - 0" at 30 degrees. + 43' - 6" from stage 0' - 0".
Gallery
2 fake apron box seating areas that are 30" deep and begin 4' - 0" off-stage of the proscenium tormentor and run 16' - 0" at 70 degrees into the house. Excellent side lighting position. Floor is +8' - 0" from stage 0' - 0".
Spot booth
Approximately 92' from proscenium. Mid-stage throw is approximately 122' - 0" at 25 degrees. +43' - 6" from stage 0' - 0".
Stage Positions:
(all battons are 65' - 0" in length)
1st Elec 2' - 6" from plaster line
2nd Elec. 8' - 6" from plaster line
3rd Elec. 18' - 0" from plaster line
4th Elec. 30' - 0" from plaster line
Drop Boxes:
(Boxes are located in grid 35' SL & SR of center line.)
Box 1 & 2 6' - 4" from plaster line
Box 3 & 4 12' - 0" from plaster line
Box 5 & 6 21' - 0" from plaster line
Box 7 & 8 26' - 6" from plaster line
Box 9 & 10 32' - 6" from plaster line
Instruments:
HFAC does not own a complete complement of lighting instruments. Arrangements must be made in advance for rental and installation.
14 10o Source 4
16 19o Source 4
16 26o Source 4
29 36o Source 4
14 Altman 6" Fresnels
06 Altman 8" Fresnels
28 Altman PAR 64
50 L&E PAR 64
08 Altman R-40 8' STRIP 4 circuit
09 Altman 3-cell 3 Farcyc
Follow Spot:
2-Lycian SuperStar, 1200 watt HB halide lamp. Spot is located in the spot booth.
Note: Follow Spots cannot be transported to other locations.
Accessories:
12' - 9" x 28' - 0" cinema screen located up-stage 4' - 9" from plaster line
Note: Cannot be removed.
1-30' JLG electric vertical lift, 1- 24' trestle ladder, 1- 10' A-frame ladder, 1- 8' A-frame ladder.
1-Panasonic CCD color camera permanently mounted in light booth and focused on stage Output terminates in sound booth and can be patched via BNC connectors. BNC connector inputs for monitors are located in the main dressing rooms, technical office, orchestra pit, SL & SR proscenium and green room.
Note: Monitors are not available.
Circuiting
Circuit Chart:
(HR to HL, SL to SR, unless noted)
Catwalk 3 5-16, P5-P6
SOUND
Sound Booth:
Back-of-house under the balcony approximately 95 feet from the plaster line
House Mix:
House-right approximately 35 feet from plaster line. 120 V duplex, intercom station, 2XLR jacks to sound booth via 2- 1/2" conduit are located in house-left special seating area.
Power:
SR Proscenium 400 Amp Disconnect 120/208 V, 3 Phase ( mostly used for lighting)
House Left Gel Storage Area 100 Amp Service 120/208V, 3 Phase or
1 spare 3 Phase 30 Amp Breaker
1 spare 3 Phase 60 Amp Breaker
Main Console:
Allen & Heath GL 3 16 x 4 x 2
Effects Mixer:
Electro-Voice Vecter 8 8 x 2 x 1 (secondary board plugged into channel on Allen & Heath)
Speaker Cluster:
Permanently mounted over the proscenium on the 1st catwalk
3 High frequency horn w/Electro-Voice DH1A Drivers
1 Electro-Voice TL15-2 Dual 15" Woofer
1 Electro-Voice CEX4L Crossover
1 Micro Audio 1.3 VQ Programmable Equalizer
1 Symmetrix 501 Limiter/Compressor
Fill Speakers:
Balcony: Permanently mounted on the third catwalk
3 Electro-Voice PRO 12B 12" Coaxial Loudspeakers
Under-balcony: Permanently mounted in ceiling
7 Atlas/ Soundolier FC54/T704: Speaker w/Trans.
1 Peavey IDL-1000 Digital Electronic Signal Delay
Effects Speakers:
House: Permanently mounted on 1st catwalk
2 Electro-Voice TL18-1 18" Direct Radiating Sub-Woofer
2 Electro-Voice S1502ER 2-way-Horn Loaded Stage
Stage: Permanently mounted on 1st catwalk
2 Electro-Voice PRO12B 12" Coaxial Loudspeakers
1 Peavey PSX Stereo Electronic Crossover
Amplifiers:
6 Electro-Voice AP2300 Stereo Power Amplifiers
2 Electro-Voice AP2600 Stereo Power Amplifiers
1 Peavey IPA150T (under balcony delay))
2 Peavey MA675T Mix/Amp (monitors)
Microphones:
1 Electro-Voice RE45ND (program pick-up only)
5 Electro-Voice RE11
5 Audio-Technica Unipoint AT853R
4 Crown PCC 160 Boundary Plate
2 Beta SM58
2 Vega Wireless Lavalier
1 Vega Wireless Handheld
1 Crown LM200B Lectern Mic.
5 Atlas/Soundolier MS20 Mic. Stands
6 Atlas/Soundolier GN19 Goosenecks
36 TJC 15' Quad Mic. Cable
10 TJC 50' Quad Mic Cable
Playback:
2 Tascam MOD 102 2 Head Cassette Deck
1 Panasonic SL-4300 Compact Disc Player
Mic Lines:
(mic. level XLR, terminates at main console patch panel)